DxLab-32A Automated Nucleic Acid Purification and Real Time PCR System

DxLab-32A integrates the functions of nucleic acid extraction and PCR analysis into one system, achieving fully automated operation, and a "sample-in-result-out" workflow. It is equipped with six fluorescence channels and can produce results in as little as 50 minutes, greatly improving detection efficiency, as well as saving a lot of manpower and time.


Features of DxLab-32A Automated Nucleic Acid Purification and Real Time PCR System

  • Minimal hands-on time: One-step manual operation with a sample in-result out workflow;

  • Fast and efficient: Maximum heating rate ≥ 10°C/s; results obtained in as fast as 50 min;

  • Multiplex: 6 channels support detecting multiple targets simultaneously in one tube;

  • Flexible throughput: 1-32 samples can be detected in parallel.

  • Full-open system: Compatible with most commercial PCR reagents and nucleic acid extraction kits.


Workflow of DxLab-32A Automated Nucleic Acid Purification and Real Time PCR System

1. Manual Operation

Samples, reagents and consumables are loaded into the instrument.

2. The Instrument Performs Experiments and Data Analysis

Nucleic acid extraction, sample transfer, PCR reaction tubes transfer, PCR reaction, and data analysis are carried out by the instrument.


Applications of DxLab-32A Automated Nucleic Acid Purification and Real Time PCR System

  • Universities and Research Institutions

Molecular research, gene expression, species identification, etc.

  • Medical Centers

Pathogen detection, tumor diagnosis, reproductive genetics, etc.

  • Customs and Airports

Entry-exit inspection and quarantine.

  • Mobile Cabins

On-site emergency testing with improved testing speed.


Specifications of DxLab-32A Automated Nucleic Acid Purification and Real Time PCR System

Parameters

Description

Throughput

1~32

Maximum Heating Rate

≥10 ℃/s

Maximum Cooling Rate

≥6.5 ℃/s

Temperature Control Precision

≤0.1℃

Reaction Volume

15~100 μL

Temperature Uniformity

±0.1℃

Nucleic Acid Extraction Consistency

≤5%

Weight

75 (±2) Kg

Voltage

AC220V

Power

1200VA

Optical Channels

6 Channels: FAM, HEX, ROX, CY5, QUASAR705, and Atto425

Fluorescence Intensity Detection Precision

≤5%

Fluorescence Intensity Detection Repeatability

≤1%

Inter-channel Fluorescence Interference Threshold

10%

Melting Curve Temperature Range

35.0℃~95.0℃

Sample Detection Repeatability

≤3%

Pipetting Accuracy

≤±5% (≤10 μL); ≤±3.5% (≤11 μL~50 μL)

Dimensions

662 mm×667 mm×519 mm

Frequency

50HZ